pumpcalc

Pipe Pressure Drop Calculator

Work out how much pressure a pipe run loses to friction and fittings. Enter the flow, pipe size and length, and the calculator gives the pressure drop in kPa, bar or psi — plus the velocity, Reynolds number and friction factor behind it.

Units:
Volumetric flow rate through the pipe.
Inside diameter — the diameter the liquid flows through.
Total length of the pipe run.
Default 0.045 mm is commercial steel. Use the value for your pipe material.
Default 1.004e-6 m²/s is water at 20 °C. Viscosity changes with temperature — enter the value for your liquid and temperature.
Add up the loss coefficients of all fittings and valves in the run.
Default 998.2 kg/m³ is water at 20 °C.

Need K values for your fittings? See the fitting loss coefficients (K values) table.

Pressure drop (Δp)
37.3 kPa
QuantityValue
Velocity1.768 m/s
Reynolds number176100
Friction factor f0.0189
Friction loss h_f3.013 m
Minor loss h_m0.7972 m
Total head loss3.811 m
Pressure drop37.3 kPa (0.373 bar)

Formula

Δp=ρg(hf+hm)\Delta p = \rho g (h_f + h_m)

hf=fLDv22ghm=ΣKv22gh_f = f \frac{L}{D} \frac{v^2}{2g} \qquad h_m = \Sigma K \frac{v^2}{2g}

v=QπD2/4Re=vDνv = \frac{Q}{\pi D^2 / 4} \qquad Re = \frac{v D}{\nu}

f=64Re(Re<2300);f=0.25[log⁡10(ε3.7D+5.74Re0.9)]2(Re>2300)f = \frac{64}{Re} \quad (Re \lt 2300); \qquad f = \frac{0.25}{\left[\log_{10}\left(\frac{\varepsilon}{3.7 D} + \frac{5.74}{Re^{0.9}}\right)\right]^2} \quad (Re \gt 2300)

SymbolMeaningUnit
ΔpPressure dropPa
ρLiquid densitykg/m³
gStandard gravity, 9.80665 m/s²m/s²
h_fFriction (major) lossm
h_mMinor loss from fittings and valvesm
fDarcy friction factor—
LPipe lengthm
DPipe inside diameterm
vMean flow velocitym/s
QVolumetric flow ratem³/s
ReReynolds number—
νKinematic viscositym²/s
εPipe roughnessm
ΣKSum of fitting loss coefficients—

The pressure drop is the head loss (friction plus fittings) converted back to pressure with Δp=ρgh\Delta p = \rho g h. The last line is the Swamee–Jain formula for the turbulent friction factor. Below Re 2300 the flow is laminar and f=64/Ref = 64 / Re. Between Re 2300 and 4000 the flow is transitional and the friction factor is unreliable — the calculator warns you when you land there.

Worked examples

Example 1 — SI: 50 m³/h through 100 mm pipe

Example 2 — US: the same system in US units

These are the SI example values converted to US units (37.30 kPa / 6.894757 = 5.41 psi; 3.81 m = 12.50 ft). Reynolds number and friction factor are dimensionless, so they do not change with the unit system.

Assumptions and limits

Next step

Want the drop as a head in metres or feet instead of a pressure? Convert it: Pressure to head calculator

Check whether the velocity in this pipe is in a sensible range, or size the pipe for a target velocity: Pipe velocity and size calculator

FAQ

What is the difference between pressure drop and head loss?

They are the same loss expressed in different units. Head loss (h_f + h_m) is in metres or feet of the liquid; pressure drop is that head converted with Δp = ρ·g·h. A head loss of 3.81 m of water at 20 °C is a pressure drop of 37.3 kPa (0.373 bar). The head loss does not depend on density, but the pressure drop does — the same 3.81 m of a heavier liquid is a larger pressure drop.

Should I use the inside or the outside diameter?

Inside diameter. The velocity, Reynolds number and friction loss all depend on the bore the liquid actually flows through. The outside diameter is larger, so using it would understate the velocity and the losses. If you only know the nominal size (DN/NPS), convert it to the actual inside diameter from the pipe schedule and wall thickness.

How do I work out ΣK for my fittings?

Look up the K value of each fitting and valve in the run and add them: ΣK is the plain sum. Typical values are listed in the fitting K values table on this site. A fully open gate valve is about 0.15, a 90° flanged elbow about 0.3, and a fully open globe valve about 10 — one globe valve can dominate the whole ΣK. If a datasheet gives an equivalent length instead of a K, convert it with K = f·(L_eq/D).

Why is the transitional range (Re 2300–4000) unreliable?

In that range the flow keeps switching between laminar and turbulent, so the friction factor is not settled: the laminar relation f = 64/Re no longer applies, and the Swamee–Jain formula is a turbulent-flow relation. The true friction factor can sit well away from either one. The calculator warns you when you land there — change the pipe size or the flow so the design point sits clearly in laminar or turbulent flow, or verify the loss by test.

Does a longer pipe always mean a proportionally larger pressure drop?

Only the friction part grows with length: h_f is proportional to L/D, so doubling the length doubles h_f. The minor loss h_m depends only on the fittings (ΣK) and the velocity, not on the length. So on a short run with many fittings the minor loss can be the larger term, while on a long straight run friction dominates.

Sources

For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.

Reviewed by pumpcalc · Last updated 2026-11-18