Pipe Pressure Drop Calculator
Work out how much pressure a pipe run loses to friction and fittings. Enter the flow, pipe size and length, and the calculator gives the pressure drop in kPa, bar or psi — plus the velocity, Reynolds number and friction factor behind it.
Need K values for your fittings? See the fitting loss coefficients (K values) table.
| Quantity | Value |
|---|---|
| Velocity | 1.768 m/s |
| Reynolds number | 176100 |
| Friction factor f | 0.0189 |
| Friction loss h_f | 3.013 m |
| Minor loss h_m | 0.7972 m |
| Total head loss | 3.811 m |
| Pressure drop | 37.3 kPa (0.373 bar) |
Formula
| Symbol | Meaning | Unit |
|---|---|---|
| Δp | Pressure drop | Pa |
| ρ | Liquid density | kg/m³ |
| g | Standard gravity, 9.80665 m/s² | m/s² |
| h_f | Friction (major) loss | m |
| h_m | Minor loss from fittings and valves | m |
| f | Darcy friction factor | — |
| L | Pipe length | m |
| D | Pipe inside diameter | m |
| v | Mean flow velocity | m/s |
| Q | Volumetric flow rate | m³/s |
| Re | Reynolds number | — |
| ν | Kinematic viscosity | m²/s |
| ε | Pipe roughness | m |
| ΣK | Sum of fitting loss coefficients | — |
The pressure drop is the head loss (friction plus fittings) converted back to pressure with . The last line is the Swamee–Jain formula for the turbulent friction factor. Below Re 2300 the flow is laminar and . Between Re 2300 and 4000 the flow is transitional and the friction factor is unreliable — the calculator warns you when you land there.
Worked examples
Example 1 — SI: 50 m³/h through 100 mm pipe
- Water at 20 °C: ,
- Flow: ; pipe: , ,
- Fittings:
- Velocity:
- Reynolds number: (turbulent)
- Friction factor (Swamee–Jain):
- Velocity head:
- Friction loss:
- Minor loss:
- Total head loss:
- Pressure drop:
Example 2 — US: the same system in US units
- Flow: ; pipe: ,
- Fittings: ; water at 20 °C
- Velocity: ; Reynolds number: ; friction factor:
- Friction loss: ; minor loss:
- Total head loss:
- Pressure drop:
These are the SI example values converted to US units (37.30 kPa / 6.894757 = 5.41 psi; 3.81 m = 12.50 ft). Reynolds number and friction factor are dimensionless, so they do not change with the unit system.
Assumptions and limits
- Incompressible liquid only. Density is treated as constant along the pipe, so this is for liquids, not gases.
- Steady flow. The calculation is for a constant flow rate; it does not cover water hammer or start-up transients.
- Swamee–Jain is an explicit approximation of the Colebrook relation for turbulent flow. Below Re 2300 the laminar relation applies. In the transitional range, Re 2300 to 4000, neither relation is reliable and the calculator shows a warning.
- Fitting K values are typical values, not exact for every fitting. The actual K depends on the exact geometry — use the manufacturer’s data for final design. The fitting K values table lists typical values per fitting.
- The roughness default (0.045 mm) is commercial steel only, from the worked example. Enter the value for your own pipe material.
- Entrance and exit losses are not added automatically. If they apply to your system, include them in the ΣK total.
- The pressure drop is the loss along this pipe run only. It does not include the static head or any pressure difference between the pipe ends — for the full head the pump must deliver, use the total dynamic head calculator.
Next step
Want the drop as a head in metres or feet instead of a pressure? Convert it: Pressure to head calculator
Check whether the velocity in this pipe is in a sensible range, or size the pipe for a target velocity: Pipe velocity and size calculator
FAQ
What is the difference between pressure drop and head loss?
They are the same loss expressed in different units. Head loss (h_f + h_m) is in metres or feet of the liquid; pressure drop is that head converted with Δp = ρ·g·h. A head loss of 3.81 m of water at 20 °C is a pressure drop of 37.3 kPa (0.373 bar). The head loss does not depend on density, but the pressure drop does — the same 3.81 m of a heavier liquid is a larger pressure drop.
Should I use the inside or the outside diameter?
Inside diameter. The velocity, Reynolds number and friction loss all depend on the bore the liquid actually flows through. The outside diameter is larger, so using it would understate the velocity and the losses. If you only know the nominal size (DN/NPS), convert it to the actual inside diameter from the pipe schedule and wall thickness.
How do I work out ΣK for my fittings?
Look up the K value of each fitting and valve in the run and add them: ΣK is the plain sum. Typical values are listed in the fitting K values table on this site. A fully open gate valve is about 0.15, a 90° flanged elbow about 0.3, and a fully open globe valve about 10 — one globe valve can dominate the whole ΣK. If a datasheet gives an equivalent length instead of a K, convert it with K = f·(L_eq/D).
Why is the transitional range (Re 2300–4000) unreliable?
In that range the flow keeps switching between laminar and turbulent, so the friction factor is not settled: the laminar relation f = 64/Re no longer applies, and the Swamee–Jain formula is a turbulent-flow relation. The true friction factor can sit well away from either one. The calculator warns you when you land there — change the pipe size or the flow so the design point sits clearly in laminar or turbulent flow, or verify the loss by test.
Does a longer pipe always mean a proportionally larger pressure drop?
Only the friction part grows with length: h_f is proportional to L/D, so doubling the length doubles h_f. The minor loss h_m depends only on the fittings (ΣK) and the velocity, not on the length. So on a short run with many fittings the minor loss can be the larger term, while on a long straight run friction dominates.
Sources
- Darcy–Weisbach head loss and the Swamee–Jain friction-factor relation — standard fluid-mechanics textbook relations
- Engineering ToolBox, "Minor (Dynamic) Loss Coefficients for Pipe and Tube System Components" — fitting K values
- Water density at temperature — see the water vapor pressure and density table on this site
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.