Fitting Loss Coefficients (K Values)
Minor loss coefficients for the fittings found in a typical pump line: elbows and bends, tees, fully open valves, and pipe entrances and exits. Use the K value with the pipe velocity to work out the head lost across each fitting.
| Note | |||
|---|---|---|---|
| 90° elbow, flanged, regular radius | Elbow/Bend | 0.3 | — |
| 90° elbow, threaded, regular radius | Elbow/Bend | 1.5 | — |
| 90° elbow, flanged, long radius | Elbow/Bend | 0.2 | — |
| 90° elbow, threaded, long radius | Elbow/Bend | 0.7 | — |
| 45° elbow, flanged, long radius | Elbow/Bend | 0.2 | — |
| 180° return bend, flanged | Elbow/Bend | 0.2 | — |
| Globe valve, fully open | Valve | 10 | — |
| Angle valve, fully open | Valve | 2 | — |
| Gate valve, fully open | Valve | 0.15 | — |
| Pipe entrance, sharp-edged | Entrance/Exit | 0.5 | — |
| Pipe entrance, rounded | Entrance/Exit | 0.05 | — |
| Pipe exit into a tank | Entrance/Exit | 1 | — |
| Tee, flanged, line flow | Tee | 0.2 | — |
| Tee, flanged, branch flow | Tee | 1 | — |
| Tee, threaded, line flow | Tee | 0.9 | — |
| Tee, threaded, branch flow | Tee | 2 | — |
| Union, threaded | Other | 0.08 | — |
| Ball valve, fully open | Valve | 0.05 | — |
| Swing check valve, fully open | Valve | 2.5 | — |
| Butterfly valve, fully open | Valve | 0.5 | Typical range 0.2–0.6 depending on disc and size |
Showing 20 of 20 fittings. Click a column heading to sort. K is dimensionless, based on the velocity inside the pipe.
Downloads the rows currently shown as a CSV file.
How to use K values
The head lost across one fitting is , where is the velocity inside the pipe and . Add the K values of all fittings in a line to get , then is the total minor loss. For example, a sharp-edged entrance () with water moving at 2 m/s loses m of head.
K values are typical, not exact. The real coefficient depends on the exact fitting geometry and the Reynolds number, so always check the value against the manufacturer’s data before final design — and if a datasheet gives a different K for your fitting, use the datasheet value. The total dynamic head calculator lets you edit any K in its fitting list.
Contraction and expansion losses are different: they depend on the diameter ratio of the two pipe sizes, so there is no single K value for a reducer or an enlargement. Work them out from the ratio (for a sudden contraction, rises steeply as the area ratio falls; for a sudden expansion, with the loss based on the upstream velocity) rather than looking them up in this table.
Data source
- Engineering ToolBox, "Minor (Dynamic) Loss Coefficients for Pipe and Tube System Components" (2004).
- US Army Corps of Engineers, EM 1110-1-4008, Table 3-3 (entrance, exit, swing check and butterfly valve values).
Data checked 2026-11-18. The butterfly valve is listed as K = 0.5 with its typical range of 0.2–0.6, because published sources give a range rather than a single value for it.
Related calculators
- Total dynamic head (TDH) calculator — add fitting losses to friction and static head to find the head your pump must deliver.
- Pipe pressure drop calculator — the same losses expressed as a pressure drop instead of head.
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.