Fitting Loss Coefficients (K Values)

Minor loss coefficients for the fittings found in a typical pump line: elbows and bends, tees, fully open valves, and pipe entrances and exits. Use the K value with the pipe velocity to work out the head lost across each fitting.

Note
90° elbow, flanged, regular radiusElbow/Bend0.3—
90° elbow, threaded, regular radiusElbow/Bend1.5—
90° elbow, flanged, long radiusElbow/Bend0.2—
90° elbow, threaded, long radiusElbow/Bend0.7—
45° elbow, flanged, long radiusElbow/Bend0.2—
180° return bend, flangedElbow/Bend0.2—
Globe valve, fully openValve10—
Angle valve, fully openValve2—
Gate valve, fully openValve0.15—
Pipe entrance, sharp-edgedEntrance/Exit0.5—
Pipe entrance, roundedEntrance/Exit0.05—
Pipe exit into a tankEntrance/Exit1—
Tee, flanged, line flowTee0.2—
Tee, flanged, branch flowTee1—
Tee, threaded, line flowTee0.9—
Tee, threaded, branch flowTee2—
Union, threadedOther0.08—
Ball valve, fully openValve0.05—
Swing check valve, fully openValve2.5—
Butterfly valve, fully openValve0.5Typical range 0.2–0.6 depending on disc and size

Showing 20 of 20 fittings. Click a column heading to sort. K is dimensionless, based on the velocity inside the pipe.

Downloads the rows currently shown as a CSV file.

Source: Engineering ToolBox, Minor (Dynamic) Loss Coefficients for Pipe and Tube System Components; US Army Corps EM 1110-1-4008 Table 3-3. Data checked 2026-11-18.

How to use K values

The head lost across one fitting is hm=K⋅v2/(2g)h_m = K \cdot v^2 / (2g), where vv is the velocity inside the pipe and g=9.80665 m/s2g = 9.80665\ \text{m/s}^2. Add the K values of all fittings in a line to get ΣK\Sigma K, then hm=ΣK⋅v2/(2g)h_m = \Sigma K \cdot v^2 / (2g) is the total minor loss. For example, a sharp-edged entrance (K=0.5K = 0.5) with water moving at 2 m/s loses 0.5×22/(2×9.81)≈0.100.5 \times 2^2 / (2 \times 9.81) \approx 0.10 m of head.

K values are typical, not exact. The real coefficient depends on the exact fitting geometry and the Reynolds number, so always check the value against the manufacturer’s data before final design — and if a datasheet gives a different K for your fitting, use the datasheet value. The total dynamic head calculator lets you edit any K in its fitting list.

Contraction and expansion losses are different: they depend on the diameter ratio of the two pipe sizes, so there is no single K value for a reducer or an enlargement. Work them out from the ratio (for a sudden contraction, KK rises steeply as the area ratio falls; for a sudden expansion, K=(1−A1/A2)2K = (1 - A_1/A_2)^2 with the loss based on the upstream velocity) rather than looking them up in this table.

Data source

Data checked 2026-11-18. The butterfly valve is listed as K = 0.5 with its typical range of 0.2–0.6, because published sources give a range rather than a single value for it.

For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.