Pump Operating Point Calculator
Find the flow and head where your pump will actually run: fit a curve through three points from the manufacturer’s pump curve, describe the system with a static head and a resistance coefficient, and solve for the intersection.
Enter three points from the pump curve — the shutoff point (flow 0) and two more points from the manufacturer's curve. The calculator fits a parabola through them and finds where it meets your system curve.
Flow is in m³/h and head in m — pump curves are published in m³/h or gpm, and the fit is done in those working units.
K = 0.001563 m/(m³/h)²
Fitted pump curve: H = 50 + 0.025·Q + -0.0025·Q² (m, Q in m³/h)
Next step: Send 95.95 m³/h at 29.38 m to the pump power calculator →
Formula
| Symbol | Meaning | Unit |
|---|---|---|
| H_pump(Q) | Pump head at flow Q, fitted as a parabola | m |
| a, b, c | Fitted coefficients; a is the shutoff head (head at Q = 0) | m, m/(m³/h), m/(m³/h)² |
| Q | Volumetric flow rate | m³/h |
| H_sys(Q) | System head at flow Q | m |
| H_static | Static head: the lift the pump must overcome before any friction | m |
| K | System resistance coefficient, K = h_f / Q² | m/(m³/h)² |
| h_f | Friction head at a reference flow | m |
Three points from the pump curve determine the parabola exactly — the shutoff point fixes , and the other two points fix and . The system curve is a parabola too: the static head plus a friction term that grows with the square of the flow. Setting the two equal gives a quadratic equation; its smallest positive root is the operating flow, and either curve gives the operating head.
Worked examples
Example 1 — SI: pump points (0, 50), (40, 47), (80, 36) m
- Pump curve points: , , — flow in m³/h, head in m
- From the shutoff point:
- The other two points give and , so and
- Fitted curve:
- System: static head ; friction at , so
- Intersection: , i.e.
- Operating point: ;
The operating flow sits beyond the highest fitted point (80 m³/h), so check it against the real pump curve — the fit is an extrapolation there.
Example 2 — US: pump points (0, 150), (200, 140), (400, 110) ft
- Pump curve points: , , — flow in gpm, head in ft
- From the shutoff point: ; the other two points give and
- Fitted curve:
- System: static head ; friction at , so
- Intersection: , so
- Operating head:
Same calculation, same method — only the units change, because the fit and the system curve use one consistent set of flow and head units throughout.
Assumptions and limits
- Three-point fit is an approximation. A real pump curve is not exactly a parabola. The fit is trustworthy only inside the flow range covered by the three points — do not trust an operating point far outside that range without checking it against the manufacturer’s curve.
- The system curve assumes friction grows with Q². That holds for fully turbulent flow with a fixed system (no throttling valve being adjusted, no changing static head). If the static head changes with level, solve the operating point at each level.
- Steady state only. The calculation gives the steady running point; it does not cover start-up, shut-down or water hammer.
- The shutoff head must exceed the static head. If the pump cannot lift the liquid at all and the calculator says so — no operating point exists.
- One pump, one system. Parallel or series pump combinations need a combined pump curve first; this calculator fits a single pump curve.
- Working units are m³/h and m (SI) or gpm and ft (US). Pump curves are published in m³/h or gpm, so the fit is done in those units and the resistance K must use the same flow unit.
Next step
Got an operating point? Size the motor for it — send the flow and head to the power calculator: Pump power calculator
If you change the pump speed or trim the impeller, the curve moves — use the pump affinity laws calculator to scale the duty point first, then check the scaled point against the system curve here.
FAQ
What three points should I pick from the pump curve?
The shutoff point (flow 0, shutoff head) and two more points spread across the range you expect to run in — for example the best-efficiency point and a point near the maximum expected flow. Points bunched together make the fit unreliable, and an operating point outside the range they cover is an extrapolation, so check it against the real curve.
How do I get the system resistance K?
From any known friction loss: K = h_f / Q². If you know the system loses 10 m of head to friction at 80 m³/h, K = 10 / 80² = 0.0015625 m/(m³/h)². You can work out the friction loss with the total dynamic head calculator, then enter the loss and the flow here and the calculator computes K for you.
What does "shutoff head is below the static head" mean?
The pump at zero flow produces its shutoff head — the most head it can ever make. If that is less than the static lift the system demands, the pump cannot push any liquid up at all: flow is zero and there is no operating point. You need a pump with a higher shutoff head or a lower static lift.
Why are there two roots, and which one is the operating point?
Two parabolas can cross twice. The smaller positive root is the stable operating point a centrifugal pump settles at. The larger root, when it exists, is an unstable crossing the pump will not stay at — the calculator takes the smaller one.
My operating point is outside the fitted range. Is it wrong?
Not necessarily wrong, but not verified either. The parabola is only guaranteed to pass through the three points you gave it; beyond them it is a guess. In the SI worked example the operating point (96 m³/h) sits beyond the highest fitted point (80 m³/h) — treat that as a warning to check the real curve, or re-fit with points that bracket 96 m³/h.
Sources
- processconvert, "System Curve vs Pump Curve" — H_sys = H_static + K·Q² and the K = h_f / Q² relation
- Logoscalc, "Pumps in Series" — three-point curve fitting and the closed-form intersection
- Total dynamic head calculator on this site — work out the friction loss for K
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.