ISO 9906 Pump Test Tolerance Calculator
Find the acceptance range for a pump’s guaranteed flow, head and efficiency under ISO 9906 — pick the acceptance grade, enter the guaranteed duty point, and see the lowest values a test may return while the pump still passes.
Formula
For pumps below 10 kW shaft power (ISO 9906:2012 §4.4.2), the grade table is replaced by:
| Symbol | Meaning | Unit |
|---|---|---|
| τQ | Flow tolerance, percent of guaranteed flow | % |
| τH | Head tolerance, percent of guaranteed head | % |
| τP | Power tolerance, percent of guaranteed power (upper limit only) | % |
| τη | Efficiency tolerance, percent of guaranteed efficiency (lower limit only) | % |
| P₂ | Shaft power, maximum in the operating range | kW |
Acceptance tolerances by grade (ISO 9906:2012 Table 8):
| Grade | Flow τQ | Head τH | Power τP | Efficiency τη |
|---|---|---|---|---|
| 1U | +10% | +6% | +10% | 0% |
| 1E | ±5% | ±3% | +4% | 0% |
| 1B | ±5% | ±3% | +4% | −3% |
| 2B | ±8% | ±5% | +8% | −5% |
| 2U | +16% | +10% | +16% | −5% |
| 3B | ±9% | ±7% | +9% | −7% |
Grades 1U and 2U are one-way: flow and head are only guaranteed not to fall below the guaranteed value, so the tolerance applies upward only. In the other grades the tolerance is two-way. Power is always limited upward only, and efficiency downward only.
Worked examples
Example 1 — SI: grade 2B, 100 m³/h at 50 m
- Guaranteed: , , ; shaft power
- Grade 2B: , , ,
- Flow: to
- Head: to
- Efficiency:
Example 2 — US: grade 1B, 500 gpm at 100 ft
- Guaranteed: , , ; shaft power
- Grade 1B: , , ,
- Flow: to
- Head: to
- Efficiency:
Example 3 — Small pump: 5 kW shaft power
- Guaranteed: , , ; shaft power
- Below 10 kW, ISO 9906:2012 §4.4.2 replaces the grade table, whatever grade was specified
- ;
- Flow: to
- Head: to
- Efficiency:
Assumptions and limits
- Tolerances are percentages of the guaranteed values. They apply at the guarantee point (the duty point written in the contract or datasheet), not across the whole pump curve.
- Power and efficiency cannot both be guaranteed. ISO 9906 allows only one of the two to be a guaranteed value at a duty point. If efficiency is guaranteed, the power tolerance still caps how far the measured power may exceed the expected power; if power is guaranteed, no efficiency tolerance applies.
- Default grade is 3B. When the contract or order does not specify an acceptance grade, ISO 9906 defaults to grade 3B — the widest two-way grade.
- Small pumps get wider tolerances. Below 10 kW shaft power, §4.4.2 applies instead of the grade table, and the efficiency tolerance widens as the pump gets smaller (at 5 kW it is −12%, at 1 kW it reaches −16%).
- Shaft power is the maximum in the operating range. Use the highest shaft power the pump reaches in its operating range, not the power at the guarantee point alone. If you only know flow and head, find the shaft power with the pump power calculator.
- One-way grades guarantee a minimum. Under 1U and 2U, a test that returns more flow or head than guaranteed still passes — only falling short fails.
Next step
Tolerances checked? Find where the pump actually runs on its system curve: Pump operating point calculator
FAQ
Which acceptance grade applies if the contract does not name one?
Grade 3B. ISO 9906 defaults to 3B when no grade is specified: flow ±9%, head ±7%, power +9%, efficiency −7%. If you need tighter acceptance, the grade must be agreed and written into the contract before the test.
Can power and efficiency both be guaranteed at the same duty point?
No. ISO 9906 allows only one of the two to be guaranteed. Grades 1B, 2B and 3B carry a negative efficiency tolerance (measured efficiency may fall short by 3%, 5% or 7%), while grade 1E allows no downward efficiency tolerance at all — if efficiency is guaranteed under 1E, the test must meet it in full. Power, when it is the guaranteed quantity, is always limited upward only.
What does a one-way grade such as 1U or 2U mean?
The pump is only guaranteed not to fall short. Under 1U, flow may test anywhere from the guaranteed value up to +10% above it, and head from the guaranteed value up to +6% above it. A pump that delivers more than guaranteed still passes — which suits buyers who care mainly that the pump does at least what was promised.
Why are the tolerances wider for pumps below 10 kW?
Small pumps are harder to test accurately relative to their size, so ISO 9906:2012 section 4.4.2 gives them wider tolerances when nothing else is agreed: flow ±10%, head ±8%, and an efficiency tolerance that widens as shaft power falls, from −7% at 10 kW to −17% near zero. The calculator applies this rule automatically when the shaft power you enter is below 10 kW.
Do the tolerances apply at any flow, or only at the guarantee point?
Only at the guarantee point (and any other duty points explicitly guaranteed in the contract). The rest of the pump curve is checked against the manufacturer's published curve, not against these percentages — a pump can pass its guarantee point and still be off-curve elsewhere.
Sources
- ISO 9906:2012, Table 8 — acceptance grades and tolerances (via ANSI/HI 14.6)
- Waterways Europe, "Lab results in ISO 9906 certification terms" — ANSI/HI 14.6 Table 1
- Construction Industry Council, "Water Pump Assessment Standard v2" — same tolerance table
- Pump Industry Australia, "Pump Technical Handbook: Pump Testing" — same tolerance table, notes 2B as the most commonly used grade
- DIN EN ISO 9906:2013-03, section 4.4.2 — tolerances for pumps below 10 kW shaft power
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.