ISO 9906 Pump Test Tolerance Calculator

Find the acceptance range for a pump’s guaranteed flow, head and efficiency under ISO 9906 — pick the acceptance grade, enter the guaranteed duty point, and see the lowest values a test may return while the pump still passes.

Units:
Grade 3B is the default when no grade is specified.
Max shaft power in the operating range. Below 10 kW the wider small-pump tolerances apply.
Flow at the guarantee point, from the datasheet or contract.
Head at the guarantee point.
Leave blank if only flow and head are guaranteed.
Grade 3B: flow ±9%, head ±7%, power +9%, efficiency -7%
Acceptable flow range
91 – 109 m³/h
Acceptable head range
46.5 – 53.5 m
Minimum acceptable efficiency
69.75 %
Measured efficiency must be at least this. Power tolerance: measured power must not exceed the guaranteed power by more than +9%.

Formula

Qmin=Qg⋅(1+τQ100)Hmin=Hg⋅(1+τH100)ηmin=ηg⋅(1+τη100)Q_{min} = Q_g \cdot \left(1 + \frac{\tau_Q}{100}\right) \qquad H_{min} = H_g \cdot \left(1 + \frac{\tau_H}{100}\right) \qquad \eta_{min} = \eta_g \cdot \left(1 + \frac{\tau_\eta}{100}\right)

For pumps below 10 kW shaft power (ISO 9906:2012 §4.4.2), the grade table is replaced by:

τQ=±10%τH=±8%τη=−[10⋅(1−P210)+7]%τP,gr=72+τη2 %\tau_Q = \pm 10\% \qquad \tau_H = \pm 8\% \qquad \tau_\eta = -\left[10 \cdot \left(1 - \frac{P_2}{10}\right) + 7\right]\% \qquad \tau_{P,gr} = \sqrt{7^2 + \tau_\eta^2}\ \%

SymbolMeaningUnit
τQFlow tolerance, percent of guaranteed flow%
τHHead tolerance, percent of guaranteed head%
τPPower tolerance, percent of guaranteed power (upper limit only)%
τηEfficiency tolerance, percent of guaranteed efficiency (lower limit only)%
P₂Shaft power, maximum in the operating rangekW

Acceptance tolerances by grade (ISO 9906:2012 Table 8):

GradeFlow τQHead τHPower τPEfficiency τη
1U+10%+6%+10%0%
1E±5%±3%+4%0%
1B±5%±3%+4%−3%
2B±8%±5%+8%−5%
2U+16%+10%+16%−5%
3B±9%±7%+9%−7%

Grades 1U and 2U are one-way: flow and head are only guaranteed not to fall below the guaranteed value, so the tolerance applies upward only. In the other grades the tolerance is two-way. Power is always limited upward only, and efficiency downward only.

Worked examples

Example 1 — SI: grade 2B, 100 m³/h at 50 m

Example 2 — US: grade 1B, 500 gpm at 100 ft

Example 3 — Small pump: 5 kW shaft power

Assumptions and limits

Next step

Tolerances checked? Find where the pump actually runs on its system curve: Pump operating point calculator

FAQ

Which acceptance grade applies if the contract does not name one?

Grade 3B. ISO 9906 defaults to 3B when no grade is specified: flow ±9%, head ±7%, power +9%, efficiency −7%. If you need tighter acceptance, the grade must be agreed and written into the contract before the test.

Can power and efficiency both be guaranteed at the same duty point?

No. ISO 9906 allows only one of the two to be guaranteed. Grades 1B, 2B and 3B carry a negative efficiency tolerance (measured efficiency may fall short by 3%, 5% or 7%), while grade 1E allows no downward efficiency tolerance at all — if efficiency is guaranteed under 1E, the test must meet it in full. Power, when it is the guaranteed quantity, is always limited upward only.

What does a one-way grade such as 1U or 2U mean?

The pump is only guaranteed not to fall short. Under 1U, flow may test anywhere from the guaranteed value up to +10% above it, and head from the guaranteed value up to +6% above it. A pump that delivers more than guaranteed still passes — which suits buyers who care mainly that the pump does at least what was promised.

Why are the tolerances wider for pumps below 10 kW?

Small pumps are harder to test accurately relative to their size, so ISO 9906:2012 section 4.4.2 gives them wider tolerances when nothing else is agreed: flow ±10%, head ±8%, and an efficiency tolerance that widens as shaft power falls, from −7% at 10 kW to −17% near zero. The calculator applies this rule automatically when the shaft power you enter is below 10 kW.

Do the tolerances apply at any flow, or only at the guarantee point?

Only at the guarantee point (and any other duty points explicitly guaranteed in the contract). The rest of the pump curve is checked against the manufacturer's published curve, not against these percentages — a pump can pass its guarantee point and still be off-curve elsewhere.

Sources

For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.