Pump Energy Cost Calculator
Work out what a pump costs to run — electrical input power, energy used per year, and the electricity bill per year, per day and per hour — from flow, head, pump and motor efficiency, running hours and your electricity tariff. Free, no login.
Running hours per year: 16 h/day × 365 days = 5840 h/year.
Formula
| Symbol | Meaning | Unit |
|---|---|---|
| P_h | Hydraulic (water) power | kW |
| P_s | Shaft power | kW |
| P_in | Electrical input power | kW |
| ρ | Liquid density | kg/m³ |
| g | Standard gravity, 9.80665 m/s² | m/s² |
| Q | Flow rate | m³/s |
| H | Head | m |
| η_pump | Pump efficiency (as a fraction) | — |
| η_motor | Motor efficiency (as a fraction) | — |
| E | Energy used per year | kWh/year |
| C | Energy cost per year | per year |
Hydraulic power is the power given to the liquid. Shaft power is what the motor must deliver, and input power is what the meter sees — each step up the chain divides by an efficiency, so input power is always the largest of the three. Multiply input power by running hours for the year’s energy, and by the tariff for the year’s cost. The cost comes out in the same currency as the tariff you enter.
Worked examples
Example 1 — SI: 120 m³/h at 32 m head, 6000 h/year
- Flow: ; head: ; density:
- Efficiencies: , ; running time 6000 h/year; tariff
- ;
- — about 30.50 USD per day, 1.85 USD per hour.
Example 2 — US: 50 gpm at 150 ft head, 8 h/day
- Flow: ; head: ; SG 1.0
- Efficiencies: , ; running time 8 h/day × 365 days = 2920 h/year; tariff
- Water horsepower ; brake (shaft) horsepower
- Input power
- ;
The horsepower figures above come from the US shortcut formula (divide by 3960), which uses a rounded constant. The exact SI calculation this page uses gives 1.90 water hp and 2.92 shaft hp, with , and — within 0.2% of the shortcut figures.
Assumptions and limits
- Steady average load. The calculation is for one duty point run at a constant flow and head. A pump that runs at several duties, or is throttled, should be costed duty by duty — the average input power is not the power at the average flow, because power rises faster than flow.
- Efficiencies are at the duty point. Enter pump and motor efficiency at the flow and head you entered, from the pump curve and the motor datasheet. Efficiency falls off at part load, so a throttled or oversized pump costs more than this estimate.
- Excludes VFD losses. If a variable-frequency drive is fitted, its losses (typically 2–4%) sit between the meter and the motor and are not included — divide the input power by the VFD efficiency to add them.
- Excludes demand charges, fixed fees and time-of-use tariffs. Only the per-kWh energy charge is counted. Demand (kW) charges, standing charges and peak/off-peak rates are billed separately and can dominate the bill for large motors.
- Constant tariff. The tariff is taken as one flat rate for the whole year. If your price varies by season or time of day, split the running hours across the rates and add the parts.
- Standard gravity. The calculator uses . Local gravity varies by less than 0.3% worldwide.
Next step
Slowing the pump cuts power with the cube of speed — see how much a lower speed saves on this bill: Pump affinity laws calculator
Need the power numbers first? The pump power calculator gives hydraulic and shaft power and picks a motor size.
FAQ
What is the difference between shaft power and input power?
Shaft power is the mechanical power the motor delivers at its shaft — hydraulic power divided by pump efficiency. Input power is the electrical power drawn from the supply — shaft power divided by motor efficiency. Input power is always larger, and it is the number the electricity meter (and this calculator) uses for cost.
Why is my electricity bill higher than this estimate?
Common reasons: a VFD between the meter and the motor (its 2–4% losses are not included here), demand (kW) charges and fixed fees on the bill, running at part load where efficiency is lower than at the duty point, and throttling, which wastes power across the valve. This calculator counts only the per-kWh energy charge at one steady duty point.
How do I cut a pump’s running cost?
The biggest lever is speed: the affinity laws say power falls with the cube of speed, so running at 80% speed uses about half the power (0.8³ = 0.51) — see the affinity laws calculator. Other options are a right-sized pump running near its best efficiency point instead of a throttled oversized one, and a higher-efficiency motor.
What tariff should I enter?
The per-kWh price you actually pay for the energy, in your own currency — the result comes out in that same currency. For a rough total cost, use your blended rate including taxes and delivery; for judging whether a change (a VFD, a new pump) pays back, use your marginal rate, the price of the next kWh. Demand charges and fixed fees are not included here.
Does this include VFD losses?
No. The chain here is hydraulic power → shaft power (÷ pump efficiency) → input power (÷ motor efficiency). A VFD adds one more division: input power from the meter is P_in ÷ VFD efficiency, typically 2–4% higher than shown.
Sources
- Ceon Euro, "Pump Energy Cost Calculator" — SI worked example (120 m³/h, 32 m, 72%/94%, 6000 h, $0.12/kWh)
- NRTechStudio, "Pump Horsepower Calculator" — US worked example (50 gpm, 150 ft, 65%/90%, 8 h/day, $0.15/kWh)
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.