Control Valve Sizing Calculator (Liquid)
Find the flow coefficient a liquid control valve needs — required Kv and Cv — from flow, upstream and downstream pressure, and the valve’s liquid pressure recovery factor, with a choked-flow check per IEC 60534-2-1. Free, no login.
Pressure drop 2 bar is below the choked drop 4.842 bar — flow is not choked, and the valve is sized on the full drop.
Formula
| Symbol | Meaning | Unit |
|---|---|---|
| Kv | Required metric flow coefficient | m³/h at 1 bar drop |
| Cv | Required US flow coefficient | US gpm at 1 psi drop |
| Q | Flow rate | m³/h |
| SG | Specific gravity of the liquid | — |
| Δp | Pressure drop across the valve, p₁ − p₂ | bar |
| Δp_choked | Choked (maximum effective) pressure drop | bar |
| p₁, p₂ | Upstream and downstream absolute pressure | bar |
| p_v | Vapour pressure at the flowing temperature | bar |
| p_c | Liquid critical pressure (water: 220.6 bar) | bar |
| F_F | Liquid critical pressure ratio factor | — |
| F_L | Liquid pressure recovery factor (valve type) | — |
Kv is defined in m³/h at 1 bar drop, so this calculator works in m³/h and bar internally (US inputs are converted first). If the actual drop Δp reaches the choked drop Δp_choked, the flow is choked: the vena contracta pressure has fallen to vapour pressure, the liquid starts to flash, and a larger drop cannot push more flow through. In that case the sizing drop Δp_sizing is the choked drop, not the full drop — and the valve is at risk of cavitation. Enter the water temperature and the calculator fills in vapour pressure from the water table; override it for another liquid.
Worked examples
Example 1 — SI: non-choked, water at 20 °C
- Flow: , SG 1.0; , ; at 20 °C; (globe valve)
- ;
- — not choked, so
- ;
Example 2 — SI: choked, same valve, lower downstream pressure
- Same as Example 1, but , so
- is unchanged at , and — the flow is choked
- ;
Note the required Kv is smaller when choked: the valve can only use 4.84 bar of the 5.5 bar drop. The remaining drop is wasted across the valve and the flashing liquid is likely to cavitate — check the valve and the downstream piping, and consider a valve with a higher or a larger drop taken elsewhere in the system.
Example 3 — US: 44 gpm at 87 psi(a)
- Flow: (); (); ();
- as in Example 1; ()
- — not choked; ()
Assumptions and limits
- Liquid only. The formulas are for incompressible liquids in turbulent flow. They do not cover gases, steam, flashing two-phase flow, or laminar flow (low Reynolds number).
- Turbulent, non-choked basis. The Kv equation itself assumes turbulent flow without choking; the choked-flow check caps the usable drop, but a choked result is a warning to rethink the selection, not a design target.
- F_p = 1. No correction for reducers or expanders fitted to the valve inlet or outlet. If the valve is smaller than the line, the piping geometry factor F_p reduces the effective coefficient — apply the manufacturer’s correction.
- No Reynolds number correction. At low Reynolds numbers (viscous liquids, small flows) the required Kv is larger than calculated. Check viscous service against the manufacturer’s data.
- Critical pressure is water’s. F_F uses p_c = 220.6 bar, the critical pressure of water. For another liquid, p_c differs and F_F shifts slightly — the effect is small at ordinary temperatures, but use the liquid’s own p_c for a final selection.
- F_L is a typical value unless you enter the manufacturer’s figure. The presets (globe/single-seat 0.90, ball and butterfly 0.65) are typical values; the actual F_L depends on the valve’s trim and must come from the manufacturer’s data for a final selection.
- The result is a required flow coefficient — not a valve size or model. Pick a valve whose rated Kv at a sensible travel (typically 60–80% open at the duty point) is at or above the required Kv, then check noise, cavitation and the manufacturer’s sizing data.
Next step
Need the coefficient in the other unit, or the flow a valve with a known Kv passes? Convert and check it here: Kv to Cv converter
Choked flow means the valve may cavitate — the same vapour-pressure check sits behind the NPSH available calculator, which works out whether a pump inlet has enough suction head to avoid cavitation.
FAQ
What is choked flow in a control valve?
When the pressure at the valve’s narrowest point (the vena contracta) falls to the liquid’s vapour pressure, the liquid starts to flash into vapour and the flow stops increasing, however much larger the drop across the valve becomes. The maximum effective drop is Δp_choked = F_L²(p₁ − F_F·p_v). A choked valve is sized on that drop, not the full drop — and it is likely to cavitate, so a choked result is a warning to change the selection.
What F_L should I use if the manufacturer does not give one?
Use the typical values as a starting point: about 0.90 for a globe or single-seat valve, about 0.6–0.7 for a ball or butterfly valve (this calculator uses 0.65). But F_L depends on the valve’s trim and the manufacturer’s test data — for a final selection, always use the manufacturer’s published F_L for the exact valve and trim.
Do I enter absolute or gauge pressure?
Absolute pressure, both upstream and downstream. The choked-flow check compares pressures with vapour pressure, which is an absolute quantity — using gauge pressure understates p₁ and gives a wrong (usually too small) choked drop. At sea level, add about 1.013 bar (14.7 psi) to a gauge reading to get absolute pressure.
Kv or Cv — which one do I need?
Kv is the metric coefficient (m³/h at 1 bar drop) and Cv is the US coefficient (US gpm at 1 psi drop); they describe the same valve, Cv = 1.156 × Kv. European valve datasheets quote Kv, US datasheets quote Cv — this calculator gives you both. The Kv to Cv converter on this site converts between them and works out flow from a known coefficient.
Does this calculator pick a valve size for me?
No. It gives the required flow coefficient — the Kv (or Cv) the valve must provide at the duty point. Valve size and model come from the manufacturer’s data: pick a valve whose rated Kv at a sensible travel, typically 60–80% open, covers the required Kv, then check the manufacturer’s noise and cavitation data for the service.
Sources
- IEC 60534-2-1 — industrial-process control valves, flow capacity sizing equations for liquids
- EngineersCalc, "Control Valve Cv/Kv Sizing Calculator" — F_F and choked-drop formulas and worked example
- Multicalci, "Control Valve Sizing Calculator" — IEC 60534-2-1 §5.1 and typical F_L values
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.