Pump Power Calculator with Motor Sizing
Calculate a pump’s hydraulic and shaft power from flow, head and efficiency — then pick the next IEC standard motor size, with a margin factor you can adjust. Free, no login.
Margin-adjusted power: 19.46 kW × 1.25 = 24.32 kW — the motor must cover at least this much.
Formula
US shortcut:
| Symbol | Meaning | Unit |
|---|---|---|
| P_h | Hydraulic (water) power | kW |
| P_s | Shaft power | kW |
| ρ | Liquid density | kg/m³ |
| g | Standard gravity, 9.80665 m/s² | m/s² |
| Q | Flow rate | m³/s |
| H | Head | m |
| η | Pump efficiency (as a fraction) | — |
Hydraulic power is the power actually given to the liquid. Shaft power is what the motor must deliver, so it is larger — the pump’s inefficiency is paid for at the shaft. The motor is then sized above the shaft power by a margin factor, rounded up to the next IEC standard rating.
Worked examples
Example 1 — SI: 100 m³/h at 50 m head
- Flow:
- Head: ; density: ; efficiency:
- Margin 1.25: — the next IEC standard rating is 30 kW.
Example 2 — US: 500 gpm at 100 ft head
- Flow: ; head: ; SG 1.0; efficiency:
The US shortcut gives 18.04 hp, while the exact SI calculation gives 18.06 hp — a 0.13% difference, because 3960 is a rounded constant. This calculator uses the exact SI calculation, so it shows 18.06 hp for these inputs.
Assumptions and limits
- Incompressible liquid only. The formula assumes density does not change with pressure, so it is for liquids, not gases.
- Efficiency is pump efficiency. Enter the pump’s efficiency at the duty point, from the pump curve or datasheet. It does not include motor or VFD efficiency — those losses come after the shaft, so electrical input power is higher still.
- Motor margin is common practice, not a standard. The default margin factor (1.25 up to 22 kW, 1.15 from 22 to 55 kW, 1.10 above 55 kW) is often attributed to API 610, but no citable public source for that attribution was found. KSB states the margin may be specified by the buyer or per ISO 9905, 5199 or 9908. Treat the default as a starting point and adjust it to your specification — the input is editable.
- IEC standard ratings up to 315 kW. Motor sizes follow the IEC 60072-1 rating series (0.37 to 315 kW). If the margin-adjusted power exceeds 315 kW, the calculator shows 315 kW and a larger or special motor is needed.
- Standard gravity. The calculator uses . Local gravity varies by less than 0.3% worldwide.
- Steady duty point. The result is for one flow and head. A pump that runs across a range of duties should be checked at each duty point, especially the highest-power one.
Next step
Power sorted? Check the pump has enough NPSH available at this duty point: NPSH calculator
FAQ
Why does the US shortcut (3960) differ slightly from the exact value?
The 3960 constant is a rounded combination of unit conversions (gpm to ft³/s, ft to m, hp to watts) and standard gravity. The exact SI calculation for 500 gpm at 100 ft, SG 1.0 and 70% efficiency gives 18.06 hp, while the shortcut gives 18.04 hp — a 0.13% difference. Either is fine for sizing; this calculator uses the exact calculation.
What efficiency should I enter?
The pump efficiency at the duty point, from the pump curve or datasheet — typically 50–85% for centrifugal pumps. Do not enter motor efficiency or VFD efficiency: shaft power is what the motor must deliver, and motor and VFD losses are separate and come after it.
What is the margin factor?
A safety margin applied to shaft power before picking a motor size, so the motor is not run at its rated limit. The defaults (1.25 up to 22 kW, 1.15 from 22 to 55 kW, 1.10 above 55 kW) are common practice, not a verified standard requirement — they are often attributed to API 610, but no citable public source for that was found, and KSB notes the margin may be specified by the buyer or per ISO 9905, 5199 or 9908. Change the factor to match your specification.
What if the required power is above 315 kW?
315 kW is the largest rating in the IEC 60072-1 series used here. The calculator shows 315 kW and warns you — a larger frame, a special motor, or a different pump selection is needed. Talk to the motor manufacturer.
Does this calculator include motor or VFD efficiency?
No. It gives hydraulic power and shaft power. Electrical input power is shaft power divided by motor efficiency (and by VFD efficiency, if one is fitted) — that is the number to use for running-cost estimates.
Sources
- Engineering ToolBox, "Pump Power Calculator" — hydraulic and shaft power formulas, SI and US forms
- BBA Pumps, "Pump calculations" — equivalent pump power formula
- IEC 60072-1 — motor ratings; rating series via the ABB low-voltage motor IE efficiency table
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.