Total Dynamic Head (TDH) Calculator

Add static head, pressure head, friction loss and fitting losses to get the total head the pump must deliver. Enter the pipe and the flow, and the calculator works out the velocity, Reynolds number and friction factor along the way.

Units:
Discharge elevation minus suction elevation (z_d − z_s). Negative if the discharge is below the suction.
Absolute pressure at the suction. Equal end pressures give zero pressure head.
Absolute pressure at the discharge.
Volumetric flow rate through the pipe.
Inside diameter — the diameter the liquid flows through.
Total length of the pipe run.
Default 0.045 mm is commercial steel. Use the value for your pipe material.
Default 1.004e-6 m²/s is water at 20 °C. Viscosity changes with temperature — enter the value for your liquid and temperature.
0–100 °C. The density below is filled in from this temperature.
Water density at the temperature above — edit to override.
Minor losses:
Use this if you already know the total, e.g. from a datasheet.
Total dynamic head (TDH)
23.81 m
QuantityValue
Velocity1.768 m/s
Reynolds number176100
Friction factor f0.0189
Static head20 m
Pressure head0 m
Friction loss h_f3.013 m
Minor loss h_m0.7972 m
Total dynamic head23.81 m

Next step: Send 23.81 m to the pump power calculator →

Formula

TDH=(zd−zs)+pd−psρg+hf+hmTDH = (z_d - z_s) + \frac{p_d - p_s}{\rho g} + h_f + h_m

hf=fLDv22ghm=ΣKv22gh_f = f \frac{L}{D} \frac{v^2}{2g} \qquad h_m = \Sigma K \frac{v^2}{2g}

v=QπD2/4Re=vDνv = \frac{Q}{\pi D^2 / 4} \qquad Re = \frac{v D}{\nu}

f=64Re(Re<2300);f=0.25[log⁡10(ε3.7D+5.74Re0.9)]2(Re>2300)f = \frac{64}{Re} \quad (Re \lt 2300); \qquad f = \frac{0.25}{\left[\log_{10}\left(\frac{\varepsilon}{3.7 D} + \frac{5.74}{Re^{0.9}}\right)\right]^2} \quad (Re \gt 2300)

SymbolMeaningUnit
TDHTotal dynamic headm
z_d − z_sStatic head: discharge elevation minus suction elevationm
p_d − p_sPressure rise across the pumpPa
ρLiquid densitykg/m³
gStandard gravity, 9.80665 m/s²m/s²
h_fFriction (major) lossm
h_mMinor loss from fittings and valvesm
fDarcy friction factor—
LPipe lengthm
DPipe inside diameterm
vMean flow velocitym/s
QVolumetric flow ratem³/s
ReReynolds number—
νKinematic viscositym²/s
εPipe roughnessm
ΣKSum of fitting loss coefficients—

The last line is the Swamee–Jain formula for the turbulent friction factor. Below Re 2300 the flow is laminar and f=64/Ref = 64 / Re. Between Re 2300 and 4000 the flow is transitional and the friction factor is unreliable — the calculator warns you when you land there.

Worked examples

Example 1 — SI: 50 m³/h through 100 mm pipe

The pressure head is zero here because the suction and discharge pressures are equal — only the elevation and the losses count.

Example 2 — US: the same system in US units

Same pipe, same flow — 23.8 m is 78.1 ft. Reynolds number and friction factor are dimensionless, so they do not change with the unit system.

Assumptions and limits

Next step

Got a TDH value? Size the motor for it: Pump power calculator

FAQ

What counts as static head?

The vertical distance the pump must lift the liquid: the discharge elevation minus the suction elevation (z_d − z_s). Measure both elevations from the same datum — usually the liquid surface at the suction and the discharge point or the liquid surface at the discharge. Pipe length and friction do not belong in static head; they are counted separately as h_f.

Why is the transitional range (Re 2300–4000) unreliable?

In that range the flow keeps switching between laminar and turbulent, so the friction factor is not settled: the laminar relation f = 64/Re no longer applies, and the Swamee–Jain formula is a turbulent-flow relation. The true friction factor can sit well away from either one. The calculator warns you when you land there — change the pipe size or the flow so the design point sits clearly in laminar or turbulent flow, or verify the loss by test.

Should I use the inside or the outside diameter?

Inside diameter. The velocity, Reynolds number and friction loss all depend on the bore the liquid actually flows through. The outside diameter is larger, so using it would understate the velocity and the losses. If you only know the nominal size (DN/NPS), convert it to the actual inside diameter from the pipe schedule and wall thickness.

What roughness should I use if I do not know it?

Use the measured or typical value for your pipe material from the manufacturer — do not guess. The 0.045 mm default in this calculator is commercial steel, from the worked example only. A smoother or rougher pipe changes the friction factor, so the default is a starting point, not a specification.

Can static head be negative?

Yes. Static head is the discharge elevation minus the suction elevation, so if the discharge point is below the suction liquid level the static head is negative and it reduces the total head. Enter it with a minus sign and the calculator handles it.

Sources

For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.